Line 1: | Line 1: | ||
====== Application Development ====== | ====== Application Development ====== | ||
+ | <box green 100%> | ||
+ | This is the preferred method when writing applications on the MicroZed board using the existing runtime library together with the board support package. | ||
+ | </ | ||
+ | |||
+ | While you can load and test new custom applications quickly, the configuration of the FPGA is loaded from a flash device. This saves time compared to using the method [[first_example_microzed_sysdev|System Developer]]. What must be done when using this method? | ||
+ | |||
+ | ===== Step by Step Instructions ===== | ||
+ | - Make sure that you have a default boot loader in your flash device, see [[boot_loader]]. This must be done only once as long as you don't overwrite it. | ||
+ | - Set the jumpers on your MicroZed board as follows \\ {{ : | ||
+ | - Cycle the power. The settings of the jumpers will be read only at power-on! Hence, make sure to cycle the supply power after changing the jumper settings. A soft reset (through the JTAG or by pressing the reset button on the board will reset the board but will not sample the boot mode pins connected to the jumpers. | ||
+ | - Create a deep project and setup the project configuration as given in [[first_example_microzed|Hello World on the Avnet MicroZed Board]]. | ||
+ | - Do not specify a configuration for the FPGA part, as it will be loaded from flash. you must select a configuration file for the PL. \\ {{ :: | ||
+ | - When creating the run configuration, | ||
+ | |||
+ | ===== How Does the System Boot? ===== | ||
+ | - reset (by JTAG) | ||
+ | - load and run first stage boot loader from flash | ||
+ | - configuration of PLL, clocks, DDR by host system | ||
+ | - load PL | ||
+ | - handoff to JTAG | ||
+ | - halt | ||
+ | - reset REBOOT_STATUS register | ||
+ | - download of bin-files to OCM and DDR | ||
+ | - download of bit-file (if specified) | ||
+ | - start at address 0x100 | ||